Measuring method
DC electric resistance type
Range
Depending on probes (option)
TG-PA : for wood 3.5~50%
KG-PA : for papers, cardboard 3.5~40%
PM-PA : for mortar / plaster 0.8~15%
MC mode (moisture content) : 1~100
Mode switching
Water content % , water content comparison mode (Moisture content)
Mean value indication
Max.20 points of average values of date displayed on reading. (switch OFF to delete)
Display
LCD reading, connecting-probe indication, Hold-function indication,
High/Low limit indication, Battery-residue indication
Alarm setting
High/Low limits values setting (one of either limits is also possible)
Optimal numerical value (0.1% step) , MC : 2~99 (1 step)
Temperature compensation
Automatic temperature compensating(ON or OFF setting)
Power source
Dry battery (LR03 1.5 V)×4, Non stop running about 30 hrs,
Auto-power off, Battery residue indication.
Operating temperture
0-40℃ (non condensing)
dimensions
80(W)×35(H)×150(D) mm
Option
Probes, Moisture reading checker